Operating instructions

10 Masport I43 NEW YORK / ULTIMATE Gas Inbuilt Fireplace
INSTALLATION INSTRUCTIONS
AERATION SYSTEM
The burner aeration is factory set but may need adjusting due
to either the local gas supply, air supply or altitude.
Natural Gas: 8mm open
Propane: Fully open (rear) and fully open (front)
An aeration adjustment rod is attached to the air shutter on
each burner. The rod is used to adjust the aeration on the
burner without having to take the appliance apart. This
adjustment is performed by an authorised installer. The
factory setting should be sufficient for most installations.
Note: Any damage due to carboning resulting from im-
properly setting the aeration controls is NOT cov-
ered under warranty.
COMBUSTION & VENTILATION AIR
WARNING: This appliance needs fresh air for safe opera-
tion and must be installed with provisions for adequate
combustion and ventilation air available to the room in
which it is to be operating.
This appliance installation must conform with local codes or
in the absence of local codes, with AG 601 or NZS 5261.
Air for combustion is drawn in through the front of the unit,
therefore, the front of the unit must be kept clear of any
obstructions.
GAS PRESSURE TEST
The manifold pressure is controlled by a regulator built into the
gas control, and should be checked at the pressure test point.
Note: To properly check gas pressure, both inlet and
manifold pressures should be checked using the
valve pressure ports on the valve.
1) Make sure the valve is in the off position.
2) Loosen the screw at the outlet pressure test point, turn
captured screw counterclockwise 2 or 3 turns and then
placing tubing to gauge over test point.
3) Attach tubing to a manometer using a 8mm I.D. hose.
4) Light the pilot and turn the valve to "ON" position.
5) The pressure check should be carried out with the unit
burning and the setting should be within the limits spec-
ified on the safety label.
6) When finished reading the manometer, turn off the gas
valve, disconnect the hose and tighten the screw (clock-
wise) with a 3mm wide screwdriver closing torque: 9 in.
lbs.
Note: Use the same manner to check the inlet pressure.