Operating instructions

14 Masport I43 NEW YORK / ULTIMATE Gas Inbuilt Fireplace
INSTALLATION INSTRUCTIONS
Note: The door latch may require adjustment as the door
gasket material compresses after a few fires and
after glass replacement. Turn the latch to tighten
or loosen the latch.
3) Close the door. The latch plate must be centered around
the alignment pin. See diagram 2. If the latch plate
interferes with the corner of the stove you may want to
angle the plate slightly so the door closes more easily.
DOOR INSTALLATION
1) Open the two side doors.
2) Slide the door onto the two hinge pins making sure the two
pieces are flush together. See diagram 1.
Diagram 1
Diagram 3
Diagram 2
4) The latches should alreadybe at the proper setting. If they
are too hard or too easy to close, you may want to adjust
them by turning the latch. See diagram 3.
5) Remove the blue plastic protective coating.
6) Test the seal around the door by placing a piece of paper
between the unit and the door, close the door and try to
pull the paper out. If it slips out easily, then the door is not
properly sealed. Turn the adjustable catch to tighten or
loosen the latch. See diagram 3.
Thermostat Wire Table
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
15.24 m
9.75 m
6.10 m
3.66 m
2.71 m
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size Max. Length
CAUTION
Do not connect the millivolt wall
thermostat wires to the 240V wires.
OPTIONAL WALL THERMOSTAT
A wall thermostat may be installed if desired. Connect the
wires as per the wiring diagrams. Note that the wires are
connected to the "TH" on the gas valve. Use chart below to
determine the maximum wire length:
Note: Preferable if the thermostat is installed on an
interior wall.
Masport offers a programmable thermostat but any CSA,
ULC or UL approved millivolt thermostat, 250-750 millivolt
rated non-anticipator type thermostat may be used.