Operating instructions

16 Masport I43 NEW YORK / ULTIMATE Gas Inbuilt Fireplace
OPERATING INSTRUCTIONS
Before operating this appliance, proceed through the
following check list.
1) Read and understand these instructions before operating
this appliance.
2) Clean the burner and control compartment of lint and
house dust by brushing and vacuuming regularly. At
least once a year.
3) Never operate the appliance with any of the glass re-
moved or with the door open.
4) Verify log placement. If the pilot cannot be seen when
lighting the unit - the logs or the embers have been
incorrectly positioned.
5) The unit should never to turned off and on without a
minimum of a 60 second wait.
6) Do not operate with primary guard removed. See below.
3) If the control knob is in the "OFF" position proceed to Step
5.
4) Push in gas control knob slightly and turn clockwise to
"OFF". Knob cannot be turned from "PILOT" to "OFF"
unless knob is pushed in slightly. Do not force.
5) Wait five minutes to allow gas, that may have accumulat-
ed in the main burner compartment, to escape. If you do
smell gas, follow the instructions on the front of this
manual. If you don't smell gas continue on to the next
step.
6) Turn the gas control counterclockwise to "PILOT".
7) Push in control knob all the way and hold in. Immediately
push black button on spark igniter until pilot lights.
Continue to hold the control knob in for approximately
one minute, then release the gas control knob. The pilot
flame should continue to burn. If the pilot does not remain
lit, repeat operation allowing a longer period before
releasing gas control knob.
8) Turn gas control knob counterclockwise to "ON".
9) Use rocker switch to operate main burner.
10) Rotate the variable flame control to adjust the flame
height higher or lower.
11) Close the bottom louvre assembly and tighten the wing-
nut.
12) The door must be closed when operating the unit.
SHUTDOWN PROCEDURE
1) Use the rocker switch to turn off the main burner.
2) Open the bottom louvre assembly by turning the wing nut
and swinging the louvres out.
3) Push in the gas control knob slightly and turn clockwise
to "OFF". Do not force.
4) Disconnect all electric power to the appliance if service is
to be performed.
LIGHTING PROCEDURE
IMPORTANT: Gas cock knob cannot be turned from
"PILOT" to "OFF" unless it is partially depressed.
1) Open the left side door when lighting the pilot, but once the
pilot is lit, DO NOT operate the unit with the front glass
door open.
2) Open the bottom louvre assembly by turning the wing nut
and swinging the louvres out. (See page 8 for diagram.)
THE GUARD IS FITTED TO THIS APPLIANCE TO REDUCE
THE RISK OF INJURY FROM BURNS AND NO PART OF
IT SHOULD BE PERMANENTLY REMOVED.
FOR PROTECTION OF YOUNG CHILDREN OR THE
INFIRM, A SECONDARY GUARD IS REQUIRED.
OPERATING INSTRUCTIONS