Specifications

Masport In-built Fireplaces 11
Thermo Switch Sensor
INSTALLATION
Door Handle
Attach spring handle by rotating counter clockwise onto rod. Ensure that the rod
fits into the entire length of the spring handle.
Fan/Blower
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
WARNING:
Electrical Grounding Instructions
This appliance is equipped with a three pronged (ground-
ing) plug for your protection against shock hazard and
should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the ground-
ing prong from this plug.
3) Slide the supports into the clips. The tension holding
the clips in place may be adjusted by increasing or
decreasing the offset spacing of the clips.
4) Ensure that the power cord is not in contact with any
hot stove surfaces.
5) Push the Masport logo plate into the two holes in the
front bottom left corner of the fan.
Do not turn fan ON until your insert has reached
operating temperature or at least 30 minutes after
starting fire.
Blower/Fan Wiring Diagram
Your fan should only be installed once the unit is in place
in order to prevent any damage to the fan. To attach,
follow the instructions provided with the fan. Make sure
to install the rubber grommet to the fan housing before
it is installed on the insert.
1) Remove the protective covering from the brass
trim on the fan.
2) Align the fan support with the offset clip on the
bottom of the ashlip.
Caution: Ensure that the wires do not touch any hot
surfaces and are away from sharp edges.