Specifications

Masport In-built Fireplaces
4
INSTALLATION
This is a copy of the label that accompanies
each Ontario In-built Fireplace. We have
printed a copy of the contents here for your
review.
NOTE: Masport units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY
CERTIFIED TO COMPLY WITH
JULY 1990, PARTICULATE
EMISSION STANDARDS.
MANUFACTURED BY FPI LTD.
SIGNATURE
Jan Feb Mar Apr May June
July Aug Sept Oct Nov Dec
2001
2002
2003
DATE OF
MANUFACTURE
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. INSTALL AND USE
ONLY IN MASONRY FIREPLACE OR FACTORY BUILT FIREPLACE. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA.
LISTED FACTORY BUILT FIREPLACE INSERT
CERTIFIED FOR USE IN CANADA AND U.S.A.
MODEL: I2100M
TESTED TO: ULC S628-M91 / UL 1482-1991
REPORT NO. 632-323500 (OCT.1993)
DO NOT REMOVE THIS LABEL
105
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURED FROM INSERT BODY)
A
G
F
D
B
C
E
ADJACENT SIDEWALL
ADJACENT SIDEWALL A) 10 in / 255 mm
MANTLE B) 17 in / 510 mm
TOP FACING C 10.25 in / 260 mm
SIDE FACING D) 8 in / 205 mm
COMPONENTS REQUIRED FOR INSTALLATION: 6IN / 150MM STAINLESS STEEL LINER.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS
DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE
FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED DOOR CLOSED, OPEN TO FEED FIRE ONLY. REPLACE GLASS ONLY WITH
CERAMIC GLASS (5MM). INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR
RAPIDLY. DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.
CAUTION
HOT WHILE IN OPERATION
DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS.
READ ABOVE INSTRUCTIONS.
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5IN / 38MM
ABOVE AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST BE
PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING (E) 16 IN / 405 MM
TO FRONT AND (G) 8 IN / 205 MM TO SIDES FROM FUEL DOOR.
MADE IN CANADA 908-331 rev. 11/00
Date: Nov. 1, 2000
Filename: 908-331
Size: Above artwork is to be Printed at 80%.
Colour: Black on grey, except for what is highlighted in yellow
will be red on grey
November 14, 2001: Updated to new serial number system. Otherwise no other changes to artwork.
(Duplicate Serial #) 105
Manufactured By:
FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST., DELTA, BC V4G 1H4