Instructions

P/N 72469 Page 1
February 2013
Remove
barbed
fitting
PURGE CONVERSION INSTRUCTIONS
FOR MCP44
Description: This document provides instructions for installing a water purge pump onto the
MasterCool MCP44 window evaporative cooler.
CAUTION: Ensure unit is turned fully off and unplugged from electrical outlet.
Turn off and disconnect water source to cooler unit before proceeding.
1. Remove back of cooler by extracting 2 screws
from top and 2 screws from bottom of cooler
back.
2. Disconnect water supply tube from the water
distribution tray.
3. Remove existing hose assembly and replace with
long piece of tubing from kit.
4. Attach bracket to pump with two screws (included) and place strainer basket under pump before
installing purge pump assembly to cooler body in space provided.
Vea la página 3
para el español.
Place
strainer
screen
under pump
then secure
pump
assembly
to cooler
body.
Remove and discard
existing water hose.
Replace with long
hose from kit.

Summary of content (4 pages)