Use And Care Manual

Page 9
CHARGING A HOT
BATTERY PACK
If the battery pack is above the normal tem-
perature range, the red LED will illuminate
and the green LED will be off. When the
battery pack cools down to approximately
95°F (35°C), the charger will automatically
begin charging.
CHARGING A COLD
BATTERY PACK
If the battery pack is below the normal tem-
perature range, the red LED will illuminate
and the green LED will be off. When the
battery warms to a temperature of more
than 41°F (5°C), the charger will automati-
cally begin charging.
DEFECTIVE BATTERY
If the charger detects a problem, the red
LED will begin flashing and the green LED
will be off.
1. If registering as defective, remove and
reinsert the battery pack in the charger. If
the LED status reads “defective” a second
time, try to charge a different battery pack.
2. If a different battery pack charges nor-
mally, dispose of the defective battery pack
(see Maintenance section).
3. If a different battery pack also indicates
“defective,” the charger may be defective.
OPERATION
BATTERY CHARGING
If the battery pack is within the normal
temperature range, the green LED will begin
flashing and the red LED will be off, and the
four green LEDs on the battery pack will
flash one by one from left to right.
BATTERY FULL
After the battery is fully charged, the green
LED Light on the charger will be on and the
red LED light will be off; the green LEDs on
the battery will shine for approximately 30
minutes and then turn off.
NOTICE: The battery pack will fully charge,
but will not overcharge, if left on the charger.
NOTICE: Charger may warm with several
continuous charge cycles. This is part of the
normal operation of the charge. Charge in a
well ventilated area.