Installation Manual

ChargeMaster Plus 12/75-3, 12/100-3, 24/40-3, 24/60-3 User and Installation Manual
17
4.2.1 Monitoring
A remote panel, like the SmartRemote, Touch 5 (CZone) or EasyView 5 (MasterBus), can be used for
reading battery information. See applicable user manuals for details. The following table lists the
parameters as shown in MasterAdjust.
Parameter
Meaning
Value range
General
Device state
Shows charger state (On / Stand-by / Alarm / Off)
(read only)
Charger state
Actual state of charge process:
Off/bulk/absorption/float/suspended
(read only)
'Toggle' button
Button to toggle the charger state.
This button does not work when the ChargeMaster Plus is
switched off manually. In that case it can only be switched on with
the ON/OFF button.
On / off
Input current
Option to set the maximum AC input current level to prevent a
generator or shore fuse from overload. See section 4.2.6 for more
information. Default 20.
0-20A
AC present
Shows the presence of AC input
(read only)
Battery temp.
Temperature of the main battery bank (in °C)
(read only)
DC 1 OUT
Output 1
Output state (Off/pre-float/on)
(read only)
Output 1 V
Voltage of charge output 1
(read only)
Output 1 A
Output current of charge output 1
(read only)
Shunt device
A connected MasterShunt can be chosen for feedback on the
charged battery. Default not selected.
(read only)
DC 2 OUT
Output 2
Output state (Off/pre-float/on)
(read only)
Output 2 V
Voltage of charge output 2
(read only)
Output 2 A
Output current of charge output 2
(read only)
DC 3 IN/OUT
Output 3
Output state (Off/pre-float/on/smart input DC 3 IN/OUT)
(read only)
Output 3 V
Voltage of charge output 3
(read only)
Output 3 A
Output current of charge output 3
(read only)
Parameters marked with a
are not available in CZone.