4.2.2 Alarms
The following table lists the available alarms in MasterAdjust.
Parameter
Meaning
Alarm status
Bat. temp. error
Battery temperature too high / too low
TS error
Temperature sensor error
DC 1 OUT
Shunt mismatch
Setting for nominal voltage (12/24V) at the MasterShunt or the nominal voltage of
the MLI batteries differs from nominal voltage detected by the ChargeMaster Plus.
Check battery voltage and settings of the MasterShunt or voltage of the MLI Ultra
battery.
Reverse polarity
DC + and DC are connected in reverse (this will damage the charger)
DC 2 OUT
Reverse polarity
DC + and DC are connected in reverse (this will damage the charger)
DC 3 IN/OUT
Reverse polarity
DC + and DC are connected in reverse (this will damage the charger)
4.2.3 History
The history data shows the absolute maximum readings. The following parameters are only shown in
MasterAdjust.
Parameter
Meaning
Charger
Days running
Total run time in charger mode
DC 1 / 2 OUT
Total Ah’s
Total charged Ah’s
DC 3 IN/OUT
Total Ah’s
Total charged Ah’s
Total Ah’s in
Total charged Ah’s using DC 3 IN/OUT as input