Installation Manual

ChargeMaster Plus 12/75-3, 12/100-3, 24/40-3, 24/60-3 User and Installation Manual
19
4.2.4 Configuration settings
The configuration can be done in MasterAdjust, from a laptop or notebook connected to the
ChargeMaster Plus via a Mastervolt USB Interface. See applicable user manuals for details. The following
table lists the parameters as shown in MasterAdjust.
Notes: - DIP switch settings overrule MasterBus settings. If DIP switches are not in their default setting,
the corresponding MasterBus setting is grayed out.
- To be able to make changes to the configuration via MasterBus, DIP switch 1 must be in the
ON position.
Parameter
Meaning
Factory
setting
Value range
Device
Language
Menu language of this device
English
EN, NL, DE, FR, ES, IT,
NO, SV, FI, DA
Name
Name of this device. This name will be
recognized by all devices connected to
the network
CHG
ChargeMaster
0-12 characters
Powersave
mode
If Powersave mode is ON, the charger
will switch itself off when no AC power
is available.
If Powersave mode is OFF, the charger
stays ON even when no AC power is
available.
On
On, Off
Charger
Method
Charge method
3-Step+
3-Step+, constant
voltage
Maximum
current
Maximum DC output current
Depending on
model, 100%
Depending on model
20-100%
Battery type
Type of battery
Flooded
User defined, AGM,
Gel, Flooded, Lithium-
ion
Temp.
compensate
Temperature depended charge voltage
compensation
-0,030V/°C /
-0,060V/°C
-1,000/+1,000V/°C
DC 3 IN/OUT
Charge method DC 3 IN/OUT
Follow DC 1
Current limit, Current
limit+A, Follow DC 1,
Follow DC1 + Alt,
Constant 12V, Constant
24V*, 12V 3-Step+*,
12V Battery*
Full Current
Select if 3
rd
output is a full output
On
On, off
Maximum
current
DC 3 IN/OUT maximum DC output
current
40/20A
5-40/20A
Input threshold
Voltage threshold used to switch over
when DC 3 IN/OUT acts as VSR
13,75/27.50V
8-16/16-32V
Input current
DC 3 IN/OUT maximum DC input
current (see also section 4.2.6)
40/20A
5-40/20A