Installation Manual

20
ChargeMaster Plus 12/75-3, 12/100-3, 24/40-3, 24/60-3 User and Installation Manual
Parameter
Meaning
Factory
setting
Value range
Bulk
Voltage
Bulk voltage (@ 25°C); see section 5.4
14.40/28.80V
8-16/16-32V
Minimum time
Minimum time of the Bulk phase since
Start bulk timer
120sec
0-240sec
Start time at
Battery voltage trigger point to start the
bulk timer
13.25/26.50V
(read only)
Maximum time
Maximum time of the Bulk phase since
Start bulk timer
480 min
0-1440min
Absorption
Voltage
Absorption voltage (@ 25°C); see
section 5.4
14.25/28.50V
8-16/16-32V
Maximum time
Maximum absorption timer
240min
0-1440min
Return Amps
Return amps. If the charge current
drops below this level, the charger
switches from the Absorption to the
Float stage (% of I
max
)
6%
0-50%
Minimum time
Minimum absorption timer
15min
0-240min
Float
Voltage
Float voltage (@ 25°C); see section 5.4
13.25/26.50V
8-16/16-32V
Return to bulk
V
Return to bulk voltage; If the battery
voltage stays below this level for at least
the Return to bulk delay time, the
charger will start the Bulk stage
12.80/25.60V
8-16/16-32V
Return to bulk
sec
Return to bulk delay time, see Return to
bulk voltage
30sec
0-240sec
DC 1 OUT
Name
Name of this output
Output 1
0-16 chars
Shunt device
Selection of the MasterShunt to which
output 1 of the ChargeMaster Plus is
connected
Not selected
Not selected,
MSH + Product Name
DC 2 OUT
Name
Name of this output
Output 2
0-16 chars
DC 3 IN/OUT
Name
Name of this output
Output 3
0-16 chars
Installer menu
DIP Switch
DIP switch settings
1100000000
0 / 1
Factory settings
button
Button to reset the ChargeMaster Plus
to default settings (requires installer
rights)
Not
applicable
Not applicable
*24V models only
Parameters marked with a
are not available in CZone.