Specifications

28
8.4 ERROR MESSAGES ON THE CONSOLE
CLASS
LEVEL
ERROR CODE DESCRIPTION CONDITION
B 0140 Incline motor fail. When the incline motor is supposed to move, it does not move.
When the error happens the incline motor will be locked. The
command "initialize" is needed to unlock the incline.
C 01A0 Incline motor disconnection. When the incline position cable is not connected.
C 01A4 Main motor U phase
disconnection.
Main motor U phase disconnection.
C 01A5 Main motor V phase
disconnection.
Main motor V phase disconnection.
C 01A6 Main motor W phase
disconnection.
Main motor W phase disconnection.
C 01A8 Main motor over current. Main motor over current of 7 amps.
C 01AB Inverter Error. Internal error of the inverter.
C 01AD Motor over temperature. When a heavy user makes the motor over load over go over
current.
C 02A0 Main motor failed. The belt does not move when commanded.
C 02A1 Over AC power input voltage. Power input voltage over range.
C 02A2 Over / low DC bus voltage. Power input voltage over range.
C 02A8 Inverter circuit of motor dirve
failed.
Motor resistance closed.
C 02AD LCB over temperature. LCB over temperature.
C 02B5 Inverter senses that the normal
ratedcurrentisover150%for
over 60 seconds.
Inverter sensor is reading the normal rated current is over 10.5
amps for 60 seconds.
C 02B6 Speed up has over current. Software issue.
C 02B7 Speed down has over current. Software Issue.
C 02B8 Running status over current. Software Issue.
C 02B9 The inner memory IC data write
error.
MCB failure.
C 02BA The inner memory IC data read
error.
MCB failure.
C 02BC Ground connection or fuse error. MCB failure.
C 02BD Inverter hardware interrupt error. MCB failure.
CLASS LEVEL
Class B - Will make a record in the error log. The machine will keep working.
Class C - The machine will stop and not work.
CHAPTER 8: TROUBLESHOOTING