Installation Guide

7
Figure 13
Figure 14
9. OPERATING THE
REMOTE CONTROL
Your DC brushless motor is equipped with a
automatically learned type remote control. Restore
power to ceiling fan and test the transmitter as below
for proper operation:
Install one 23A/12V battery (included). To prevent
damage to transmitter, remove the battery if not used
for long periods of time (Fig. 13)
Restore power to ceiling fan and test for proper
operation.
A. I, II, III, IV, V and VI button:
These six buttons are used to set the fan speed as
follows:
I = minimum speed
II = low speed
III = medium low speed
IV = medium speed
V = medium high speed
VI = high speed
B. Button:
This button turns the fan off.
C. Reverse button:
This button is to control fan direction.
D. SET code setting button:
Follow the below steps to use the SET button:
a) With the fan’s power off, arrange code switches to
desired code setting.
b) After installing the unit and restoring power to the
fan, press and hold the “SET” button 1 - 5 seconds. You
must press the “SET” button within 60 seconds of
restoring power to the fan.
c) The fan will start to run and begin the control setting
process. The fan will run in both directions for a total of
approximately 5 minutes.
d) When the fan stops after approximately 5 minutes,
the control and speed setting process is complete and
the fan is ready for use.
The receiver provides the following protective function:
1. Lock position: The DC motor has a built-in safety
against obstruction during operation. If there is an
obstruction, the motor will stop and then the power will
automatically go off in 30 seconds. Remove the
obstruction and reset.
2. Over 80W protection: When the receiver detects
motor power consumption which is greater than 80W,
the receiver power will be stopped and operation will
immediately discontinue. Wait for 5 seconds and then
turn the receiver power back on.
ON ECE
1234
ON
D