Use and Care Manual

Location:
Units represented in this manual are intended for indoor use only. Be sure the loca-
tion chosen has a floor strong enough to support the total weight of the cabinet and
contents. A fully loaded unit can weigh as much as 1500 pounds. Reinforce the floor
as necessary to provide for maximum loading. For the most efficient refrigeration, be
sure to provide good air circulation inside and out.
Inside cabinet:
Do not pack refrigerator so full that air cannot circulate. The refrigerated air is dis-
charged at the top rear of the unit. It is important to allow for proper air flow from the
top rear to the bottom of the unit. Obstructions to this air flow can cause evaporator
coil freeze ups and loss of temperature or overflow of water from the evaporator
drain pan. The shelves have a rear turn up on them to prevent this. However, bags
and other items can still be located to the far rear of the cabinet. Air is broug ht into
the evaporator coil with fans mounted to the front of the coil. Prevent obstruction by
locating large boxes and tall stacks of product to the bottom of the cabinet.
Outside cabinet:
Be sure that the unit has access to ample air. Avoid hot corners and locations near
stoves and ovens. It is recommended that the unit be installed no closer than 2" from
any wall with at least 12" of clearance above the unit.
Leveling:
A level cabinet looks better and will perform better because the doors will line up
with the frames properly, the cabinet will not be subject to undue strain and the con-
tents of the cabinet will not move around on the shelves. Use a level to make sure the
unit is level from front to back and side to side. If the unit is supplied with casters, it
has already been leveled. Ensure the floor where the unit is to be located is level.
Stabilizing:
All models are supplied with casters for your convenience, ease of cleaning under-
neath and for mobility. It is very important, however, that the cabinet be installed in a
stable condition with the front wheels locked while in use. Should it become neces-
sary to lay the unit on its side or back for any reason, allow at least 24 hours before
start-up so as to allow compressor oil to flow back to the sump. Failure to meet this re-
quirement can cause compressor failure and unit damage.
4
INSTALLATION
Unit repairs will not be subject to standard unit warranties
due to improper installation procedures.
Maxxx Cold Reach-ins Manual 2012VerA:Layout 1 6/7/2012 10:47 AM Page 6