INSTALLATION
Electrical connection:
Refer to the amperage data on page 3, the serial tag, your local code or the Na-
tional Electrical Code to be sure the unit is connected to the proper power source. A
protected circuit of the correct voltage and amperage must be run for connection
of the line cord, or permanent connection to the unit.
The on/off switch must be turned to OFF and the unit discon
nected from the power source whenever performing service,
maintenancefunctions or cleaning therefrigerated area.
OPERATION
Refrigerated cycle
Refrigerators: During the refrigeration cycle, the evaporator fans will run continuously
even when one or more doors are open. The door switch will activate the lights when
opened.
1. Every 6 hours, the unit will shut off and let the evaporator coil clear up the ice, the
controller will display a defrost symbol. When the coil temperature reaches 41° F or
after 20 minutes, the unit will start to work again.
2. Anti-condensation heaters on door frames work in conjunction with the compres-
sor.
3. The factory setting for temperature range is 34 0 to 38" F
Freezers: During the refrigeration cycle the controller supplies power to the condens-
ing unit and evaporator fan motors. The evaporator fans will run at any time when
the evaporator coil temperature is below 35" F, they will also keep running during
door openings but cycle off during a defrost period. The door switch will activate the
lights when opened.
1. Every 6 hours, the unit will be off and electric heater wi ll be on to clear up the ice.
The controller will display defrost symbol. When the coil temperature reaches 45° F or
after 20 minutes, the unit will start to work again.