8
Stainless Steel Care and Cleaning
To prevent discoloration of rust on stainless steel several important steps need to be
taken. Stainless steel contains 70-80% iron which will rust. It also contains 12-30%
chromium which forms an invisible passive film over the surface which acts as a shield
against corrosion. As long as the protective layer is intact, the metal is still stainless. If
the film is broken or contaminated, outside elements can begin to break down the
steel and begin to form rust of discoloration.Proper cleaning of stainless steel requires
soft cloths or plastic scouring pads,
Cleaning solutions need to be alkaline based or non-chloride cleaners. Any cleaner
containing chlorides will damage the protective film of the stainless steel. Chlorides
are also commonly found in hard water, salts, and household and industrial cleaners.
If cleaners containing chlorides are used be sure to rinse repeatedly and dry thor-
oughly upon completion.
Routine cleaning of stainless steel can be done with soap and water. Extreme stains
or grease should be cleaned with a non-abrasive cleaner and plastic scrub pad. It is
Never use a high pressure water wash for this cleaning pro
cedure as water can damage the electrical components lo
cated near or at the condenser coil.
NEVER USE STEEL PADS, WIRE BRUSHES OR SCRAPERS!
denser coil.If heavy grease is present there are de-greasing agents available for re-
frigeration use and specifically for the condenser coils. The condenser coil may re-
quire a spray with the de-greasing agent and then blown through with compressed
air.Failure to maintain a clean condenser coil can initially cause high temperatures
and excessive run times, continuous operation with dirty or clogged condenser coils
can result in compressor failures. Neglecting the condenser coil cleaning procedures
will void any warranties associated with the compressor or cost to replace the com-
pressor.
In order to maintain proper refrigeration performance, the condenser fins must be
cleaned of dust, dirt and grease regularly. It is recommended that this be done at
least every three months. If conditions are such that the condenser is totally blocked
in three months, the frequency of cleaning should be increased. Clean the con-
denser with a vacuum cleaner or stiff brush. If extremely dirty, a commercially avail-
able condenser cleaner may be required.
Maxxx Cold Reach-ins Manual 2012VerA:Layout 1 6/7/2012 10:47 AM Page 10