Use and Care Manual

Service and Installation Manual
6
1.2 Function of LEDS
2. MAIN FUNCTIONS
2.1 HOW TO SEE THE SETPOINT
1. Push and immediately release the SET key: the display will show the set point value;
2. Push and immediately release the SET key or wait for 5 seconds to display the sensor value again.
2.2 HOW TO CHANGE THE SETPOINT
1. Push the SET key for more than 2 seconds to change the set point value;
2. The value of the set point will be displayed and the
LED starts blinking;
3. To change the set value push the or
key within 10 seconds;
4. To memory the new set point value and push theSET key again or wait 10seconds.
2.3 HOW TO START A MANUAL DEFROST
Push the
key for more than 2 seconds and a manual defrost will start
2.4 HOW TO LOCK THE KEYBOARD
1. Keep pressed the and
keys for more than 3seconds;
2. The “POF” message will be displayed and the keyboard will be locked. At this point, it will be possible only
to see the set point or the MAX or Min temperature stored;
3. If a key is pressed more than 3s the ”POF” message will be displayed.
2.5 HOW TO UNLOCK THE KEYBOARD
Keep pressed the and
keys together for more than 3seconds, until the “Pon” message is
displayed, then press or
key to select the item to check or program.
3.ALARM SIGNALS
HOW TO SEE THE ALARM AND
RESET THE RECORDED ALARM
1. Push the or
key and the
alarm signals will be displayed;
2. When the signal is displayed, hold
the SET key until the “rst” message
is displayed, and push the SET key
again, the “rst” message start
blinking and the normal temperature
will be displayed again.