Use and Care Guide

11/07/2017 PK
13
The PC board activates the water drain pump for 20 seconds, pumping out
most of the water contained in the water reservoir.
The water can be pumped out up a rise of 1.5m (59”) or
over a horizontal length of 1.5m (59”).
If water level switch 2 closes, transmitting a low-voltage current to the PC board, the PC board
activates the buzzer alarm, informing you that the drain pump, water level switch or drain tube may
be malfunctioning.
Drain System Schematic Diagram
NOTE:
The outlet of the drain hose
must be raised higher than
the water surface to prevent
the drained water from
flowing back into the water
reservoir.
WARNING!
If alarm buzzer sounds, turn
off the ice maker and the
water supply, remove all ice
from storage bin, and wipe
up any water that may have
overflowed. Check if there is
any water in water trough at
back of unit; if no water,
drainage pump may not be
receiving the proper amount
of power. Check power
source. If the problem can be
corrected, turn on the unit
again. Also check that none
of the water lines are kinked.
If the problem remains,
contact Customer Service.
Water Level Switch 1
Water Level Switch 2
PC Board