Specifications

(Make
sure
that
the
treezer
temperature
is cold enough
to close
the
bimetal.)
NOTE:
Do not short
any contacts
other
than those
specified.
Damage
to ice
maker can
result.
lce
Maker
Unplugged
O
Test
points
L
&
H
will
check
the
resistance
of the
heater
(72
ohms).
Replace
the mold and
heater
assembly
if not near
this value
(*
or
-
10
ohms).
(Ejector
blades should be
at the end
of the cycle
position.)
SERVICE
PROCEDURES
covER
-
Pull water adjustment
knob first and snap
off
cover.
Index knob
and reinstall
in
same
position
for same
water fill.
(Some
units
may
not
have
index
knobs')
Mold
Attachment
(Screw
Access
Ports)
MODULE, MOTOR
AND SUPPORT
ASSEMBLY
-
Insert
phillips
driver in access
ports
in
module. Loosen both
screws.
Disconnect
shut-off
arm.
Pull mold
from support
assembly.
To remove
module only,
remove 3
phillips
screws
and
pull
module
out of
housing,
SHUT.OFF
ARM
-
Pull out
from white bushing.
Reinsert
to
full depth. See
page
6-15
for detailed
procedure.
MOLD & HEATER
-
Remove
module and support
assembly.
Install on
new mold &
heater assembly.
BIMETAL.
Remove
module and support
assembly.
Pull out
retaining clips
with bimetal. See
page
6-14
for detailed explanation.
FILL CUP
-
Remove module and support
assembly,
Remove
ejector
blades and
shut-off arm.
Pull fill
cup up
from mold. See
page
6-16
for
complete
procedure.
EJECTOR
BLADES OR STRIPPER.
Remove module and
support assembly.
When reinstalling ejector blades,
realign
"D"
coupling
with module cam.
ACCESSING
THE
CONTROL
BOX
To
remove motor and contact assembly
f rom
control
box,
take
out 3 screws
(arrows)
and
pull
free after disconnecting
the
shut-off
arm.
Shut-Off
Arm
6-1 1