Specifications

TROUBLE
POSSIBLE CAUSE
REMEDY
E. Unit runs
continuously
but there is no cooling
in refrigerator
and
freezer
compad-
ments.
1. Substantial
loss of sealed
sys-
tem charge
(low
wattage read-
i ngs).
2. Restricted
capillary or
drier on
high
side
(low
wattage readings
while
running). Will cycle
on
overload when unit
tries to start
after
defrost cycle, or after hav-
ing been
shut off and restriction
is still
present.
3. Defective compressor.
1. Locate and repair leak before
recharg i ng.
2. Replace defective
pad
or
parts.
3. Repair or replace.
F. Unit runs
contin-
uously. The refrigera-
tor and freezer
compartment are both
too
cold
(normal
wat-
tage reading).
1. Temperature control
is defec-
tive
(shorted
contacts or not
adjusted.
Freezer
control not adjusted
properly.
2.
1. Replace
or adjust as required.
2. See
"Freezer
Cold
Control" for
proper
adjustment.
G. Unit runs contin-
uously. Refrigerator
compaftment not cold
enough but freezer
compartment is
colder than normal.
1. Air duct from freezer to
refri-
gerator
is blocked
(normal
wat-
tage readings).
1. Remove what is blocking
the air
duct. See
"Air
Flow Diagram".
7-3