Specifications

TROUBLE
POSSIBLE
CAUSE
REMEDY
R. Excessively
noisy
but
works
normally
other-
wise.
1.
Refrigerator
not level
or firmly
setting on
all four corners.
Structural
weakness
in floor.
Compressor
mounling
defec-
tive.
Poor
tubing
dress.
Compressor
operation
is
noisy
due
to inherent
conditions.
Unit
base
mounting loose.
Defrost
water
pan
raltles.
Freezer
or
condenser
fan is
noisy.
May have
defective
mo-
tor.
Containers
inside
refrigerator
rattle.
2.
3.
4.
5.
6
7
8.
9.
1.
Level
the unit,
lower
the level-
ing legs
if necessary
to
make
sure
thal unit
is firmly
on the
floor.
2.
Advise
customer.
3.
Check
and replace
if
necessary.
4.
Adjust
tubes so
they
do not
touch.
5.
Advise
customel.
6. Tighten
loose
part
or
parts.
7.
Adjust
pan
or install
foam
pad
if necessary.
8.
Replace.
Advise customer
S.
Defrost
water
dis-
posal problem.
1. Water
frozen
in drain
trough
(defective
defrost
timer,
radiant
heater
or defrost
thermostat),
2. Restriction
in
drain system.
3. May
need heater
kit
installed in
evaporator
pan.
4. Separation
of heat
exchanger.
1. Replace
defective
part
or
parts.
2.
Clean
drain system.
3. Check
and
install
pad
if needed.
4.
Install
Heat Exchanger
Sepa-
ration
Kit, RA43302.
7-7