Specifications

RTW22A
POWER
REOUIREMENT
1 1sVAC
60
Hz
0PERATTNG AMPS.
(MAX)
7.2
REFRTGERANT
CHARGE R-12(02)
5.0
coMPRESSoR
0rL CHARGE
(02)
8.5
COMPRESSOR
893 BTU
CABINET LINER
HIGH IMPACT
LAMINATED
POLYSTYRENE
DOOR
LI}IERS
HIGH IMPACT
LAMINATED
POLYSTYRENE
FOUNTAIN
HEATER
Onms
Watts
NONE
CABINET
INSULATION
FOAM
TEMPERATURE
CONTROL
(At
Normal)
Cut-Out
(Plus
or
Minus
1.SoF)
Cut-ln
(Plus
or
Minus
1.SoF)
+
230F
+
33.F
CONDENSER
FAN
COOLED
CAPILLARY
TUBE
Lenglh
Diameler
8
tt.
.036"
t.D.
DEFROST
THERMOSTAT
Cut-Out
(Plus
or minus 6oF)
Culln
(Plus
or minus
6oF)
+
470F
+
150F
DEFROST
TIMER
Defrost Cycle
Defrost
Time
AFTER
COMPRESSOR
RUNS
8 HRS.
(rorAL)
23
MtN.
DEFROST
HEATER
Ohms
Watts
25
500
DEFRoST
AMPS.
(MAX.)
DIVIDER
CHANNEL HEATER
Ohms
Watts
I JZJ
10
PERFORMANCE
TEST
DATA
The laboratory
test
data in this chart was
obtained
under the following
conditions:
(1)
power
source
of 115V AC,60
Hz,
(2)
no
door openings,
(3)
no load,
(4)
customer
control(s)
set at mid-point. The
pressures
and wattages
shown were taken:
(a)
during
a normal
running
cycle,
(b)
with
treezer ternperature
near
0"F
(ref
rigerator
temperature,
if
applicable, near
+
38oF),
(c)
no sooner than
5 minutes
after compressor
start-up. ln
the home, measurements
will vary
depending
upon
environmental
and
usage
conditions.
700F
(Ambient)
90"F
(Ambient)
110"F
(Ambient)
oh
Operating Time
KWH/24
Hours
Suction Pressure
(psig)
High Side Pressure
(psig)
Running Watts
30-40
1.6-2.0
0-3
1
00-1 20
1 65-200
55-70
2.5-3.3
0-3
1
30-1 50
165-210
100
3.8-4.9
0-4
140-170
1
55-200
9-1 0