Specifications

RTD23A
iJ
POWER REOUIREMENT
1 1sVAC
60 Hz
0PERATTNG AMPS.
(MAX) 6.6
REFRTGERANT
CHARGE
R-l 2(02)
5.0
coMPRESS0R 0rL
CHARGE
(02)
8.5
COMPRESSOR
893 BTU
GABINET LINER
HIGH IMPACT
LAMINATED
POLYSTYRENE
DOOR
LINERS
HIGH IMPACT
LAMINATED
POLYSTYRENE
FOUNTAIN
HEATER
Ohms
Watts
NONE
CABINET IIISULATION
FOAM
TEMPERATURE
CONTROL
(At
Normal)
CufOut
(Plus
or
Minus 1.5"F)
Cut-ln
{Plus
or
Minus
1.S"Fi
+
23.F
+
33"F
CONDENSEB
FAN
COOLED
CAPILLARY TUBE
Length
Diameter
I
ft.
036" t.D.
DEFROST THERMOSTAT
CufOut
(Plus
or minus 6oF)
Cut-ln
(Plus
or minus
6'F)
+
470F
+
15.F
DEFROST TIMER
Defrost
Cycle
Defrost Time
AFTER
COMPRESSOR
RUNS
8
HRS.
(rorAL)
23
MtN.
DEFROST HEATER
Ohms
Watts
ZJ
500
DEFRoST AMPS.
(MAX.)
DIVIDER
CHANNEL
HEATER
Ohms
Walts
1
323
10
PERFORMANCE
TEST
DATA
The
laboratory test
data in this
chart was obtained
under the following
conditions:
(1)
power
source of 115V AC,60
Hz,
(2)
no door
openings,
(3)
no load,
(4)
customer
control(s)
set at mid-point. The
pressures
and wattages
shown were taken:
(a)
during
a normal running
cycle,
(b)
with
treezer
temperature
near
OoF
(refrigerator
temperature,
if applicable,
near
*38oF),
(c)
no
sooner than
5
minutes
after
compressor
start-up. In the
home, measurements
will vary
depending
upon
environmental
and
usage conditions.
70"F
(Ambient)
90"F
(Ambient)
1100F
(Ambient)
o/o
Operating Time
KWH|24
Hours
Suction Pressure
(psig)
High
Side
Pressure
(psig)
Running Watts
30-40
1.6-2.0
0-3
1
00-1
20
1
65-200
55-70
2.5-3.3
0-3
1
30-1 50
165-210
100
3.8-4.9
0-4
140-170
1
55-200
9-11