Specifications

CONDENSER
FAN
All Models
The
condenser
fan
is
connected
in
parallel
with
the
compressor.
lf the
compressor
runs
but the fan
doesn't,
the
fan is
either
defective
or
disconnected.
lf neither
operates,
check
the
cold
control,
defrost
timer,
and the
cabinet
wiring.
TO
CHECK
THE
CONDENSER
MOTOR
DIRECT
1.
Disconnect
the
unit
from
power
source.
2.
Remove
the
black
insulated
cover
from
the rear
of
the
chbinet.
3. Remove
the
compressor
terminal
cover.
4. Disconnect
the
condenser
fan
motor
leads.
5. Attach
a
115
V test
cord
to
the
condenser
motor
leads
and
plug
into
a
power
source.
lf the
motor
fails
to
t'
Y
I
t
I
*
I
operate
it is
defective
and rnust
be
replaced.
REPLACING
THE
CONDENSER
FAN
MOTOR
1. Disconnect
the
unit f rom
power
source
and
remove
the
insulation
cover
from
rear
of
cabinet.
2. Remove
the
screws
that
mount
the fan
motor to
the
brackets.
3. Carefully
remove
the
fan
motor
from
the
cabinet.
4. Transfer
the
fan
blade
to
the
replacement
motor
and
make
sure it is
installed
in
the
same
manner
as the
original.
5. Install
the
motor
leads
and
ground
wire.
6. Install
those
parts
previously
removed
and test
run
the
unit.
4-33