Specifications

WATER
COMPONENTS
WATER
SUPPLY
Certain
models
are equipped
with
"through
the
door"
chilled water/ice
dispensers
and/or
automatic ice
maker.
Models
which
have these
options require
the installation
of
a cold water
supply line.
For installation
of
the
water
supply,
please
refer
to
SECTION 2
-
INSTALLATION.
WATER
VALVE
Models
equipped
with
ice maker
only
have
a
single solenoid
valve
and the valve
is
wired in
series
with
the ice
maker
fill
switch,
Models
equipped
with
ice
and
water
dispensers
have
dual solenoid
valves
with
one valve
in
series with
the ice
maker fill
switch
and the
other
valve
in
series
with the
water
actuator
switches.
Check
the
coils in
the
following
manner:
1. Disconnect
the
unit from
power
source.
2. Remove
those
parts
necessary
to
expose
the
solenoid
valve(s)
for
removal.
Disconnect
valve(s)
terminals
and
attach
ohmmeter
probes.
The
meter
should
show
continuity.
REPLACING
THE WATER
VALVE
1.
Shut
off water
and electrical
supply to
the
unit.
Remove
the machine
compartment
cover from
the rear
of the unit.
Locate
the
water
valve(s)
and remove
the
mounting
screw.
5.
Disconnect
the
water inlet
fitting
from
the
water
valve
and drain
the water
into
a container.
Disconnect
the
water
valve
outlet
lines.
Drain
water
into
a container.
6. Transfer
the
wire
leads
from the
defective
water
valve(s)
to
the
replacement.
7. Install
the replacement
valve(s)
in
the
reverse
order
of removal
and replace
those
parts
previously
removed.
Check
all
connections
for
leaks.
WATER
FILL
TUBING
Care
should
be taken
when
removing
or
replacing
the
water fill
tubing
not
to
cause
a kink,
crimp
or
bend that
will result
in
a
restriction.
2.
5-1