Specifications

RESERVOIR
TO PLASTIC
UNION
1.
Disconnect the
unit from
power
source.
2.
Remove
those
parts
necessary to
expose the reservoir
(shelves).
3. Disconnect the
union connection
at the
bottom
of
the cabinet
behind the
grille.
Drain
the water
into a container.
Union Connection
Disconnect
the
compression
nut from
the reservoir
connection.
Pull
the
compression
nut off the
tubing
and
pull
the tubing from
the
back of the
unit through
the
bottom.
The replacement
tubing
is installed
by
pushing
it through
the
grommet
inside
the
fresh food
compartment
and
pulling
the tubing
from the
back of the
unit through
the
grommet.
Leave
enough
slack to
make necessary
connections.
Installation
may
be
facilitated
by
coating the
tubing with
silicone
grease
to help
ease the tubing
through
the
grommet.
7. Install
the
parts
in the reverse
order
of removal
and avoid any
crimps,
bends or kinks
that might
cause
a
restriction
in
the tubing.
L
Turn
on the
electrical supply
and
activate
the
chilled water
dispenser.
Draw
six or
seven
glasses
of water to
remove
any trapped
air
and check
all
connections
for
leaks.
PLASTIC
UNION TO
FOUNTAIN
Disconnect
the
unit f rom
power
source.
Disconnect
the
compression
nut from
the
union
at
the
bottom of the
cabinet
behind the
grille.
Drain
the water
into
a
container.
Disconnect
the
compression nut
from
the
tube
connector
on top
of the
fountain
housing.
Pull
the
compression
nut from
the
supply tubing
fountain
connector
end.
Pull the
supply
tubing
down through
the
door
bushing
and hollow hinge
pin.
Install
the replacement
supply
tubing
by
pushing
it
up through
the
bottom
door
bushing
and hollow
hinge
pin.
Pull
enough
through
to make
the
connections.
After
all connections
have
been
made,
reconnect
the
unit to the
power
supply
and
activate the
chilled water
dispenser.
Draw
six
or seven
glasses
of water
to remove
any
trapped
air
and
check
all connections
for leaks.
lnstall
any
remaining
parts
previously
removed.
1.
2,
3.
4.
4.
5.
6,
7.
L
5-17