Specifications

WATER AND
ICE
ACTIVATING
SWITCHES
(GH|LD-PROOF
SAFETY SWTTCH)
Disconnect the unit
from
power
source.
Remove those
parts
necessary to
expose
the switches for testing.
Disconnect the leads from
the switch
being tested and attach ohmmeter
leads.
Activate the switch and take a
reading. lf the meter does not show
continuity it can be assumed the
switch is defective. IMPORTANT: The
ice dispensing
switch is
in
series
with
the freezer interlock
switch and
if the
ice dispenser switch
proves
to
be
operative, it will be necessary to
check the
interlock
switch.
FOUNTAIN
HEATER
NOTE: The fountain heater
is only on
Slde-By-Side
models.
The fountain heater
is a nesistance type
heater
used
to
evaporate any moisture
that might
accumulate from condensation.
The
fountain heater is
bonded to a
self-adhesive aluminum foil which is
shaped to fit the
outside of the fountain
housing.
1. Disconnect the
unit from
power
source.
2.
Remove the
ice
and water fountain
assembly as discussed earlier.
3.
Disconnect
the wire connectors
and
remove the wire
harness
grommet,
Disconnect
the water supply tubing. In
some cases it may
be
necessary to
remove the
door
from
the unit and
disassemble liner and
gasket.
See
door, liner
and
gasket
removal
section.
4.
Carefully
remove
the foam
seal and
disconnect the heater wire terminals.
5. Pull the foil heater
backing from the
fountain.
6. Reassemble the
parts
in the reverse
order of removal.
1.
2.
3.
4.
REPLACING
THE ICE
DISPENSER
SAFETY
DOOR
The door. is designed to
prevent
entry
into the ice
dispenser chute when the
auger
is rotating. Remove the screws that
mount the ice chute collar assembly. The
door can be removed from the collar.
5-23