Service This manual is to be used by qualified appliance technicians only. Maytag does not assume any responsibility for property damage or personal injury for improper service procedures done by an unqualified person.
Important Information Important Notices for Servicers and Consumers Maytag will not be responsible for personal injury or property damage from improper service procedures. Pride and workmanship go into every product to provide our customers with quality products. It is possible, however, that during its lifetime a product may require service.
Table of Contents Important Information Important Notices for Consumers and Servicers .... 2 Recognize Safety Symbols, Words, and Labels ... 2 Important Safety Information General Information ............................................... 4 Related Publications ............................................. 4 General Precautions and Warnings ....................... 4 Product Warning Labels Junction Box Warning ........................................... 5 Support Panel Warning ..............................
Important Safety Information ! WARNING ! WARNING To avoid personal injury or death from improper servicing, make sure you read and understand the descriptions and meaning of various safety symbols, words and labels used in this manual, before attempting any procedures described in the manual. Failure to understand and comply with safety information may result in severe personal injury or death.
Important Safety Information PRECAUCIÓN: Desconecte la energía eléctrica antes de darie servicio. ATENCIÓN: Solamente use conductores de cobre. Use cables de suministro adecuados para 75° (167°F). CAUTION: Disconnect electrical power before servicing. ATTENTION: Use copper conductors only. Use supply wires suitable for 75°C (167°F). ATTENTION: Débrancher de l'alimentation électrique avant tout dépannage. ATTENTION: Utiliser des conducteurs en cuivre uniquement.
16022783 Rev. 0 ©2004 Maytag Appliances Company power is disconnected. Capacitors on control may remain active after electrical power is disconnected. Failure to follow these instructions can result in death, serious injury, fire, or electrical shock. ADVERTENCIA: Desconecte la energí antes de darle servicio. El control electrónico está energizado todo el tiempo hasta que se desconecta la energía. Los capacitores del control podrían permanecer activos después de desconectar la energía eléctrica.
Electrical Equipment & Testing Electrical Test Equipment The equipment required to service these models depends largely upon the condition encountered. Locating a malfunction will often require the use of electrical testing equipment such as: Appliance Test Meter Clamp-On Ammeter Motor Test Cord Digital Test Meter can be used to check for open or closed circuits, measure resistance, AC and DC volts, and temperature.
ELECTRICAL EQUIPMENT & TESTING VOLTAGE CHECKS Use of Ammeter on dishwasher: Generally, these checks will consist of taking readings at the wall receptacle in order to determine the availability of voltage to the product. Voltage checks on individual components of a product are not recommended due to the possibility of electrical shock. Component part testing is best accomplished through continuity checks with an Appliance Test Meter. 1.
Electrical Equipment & Testing for protection against shock hazard and should be plugged directly into a properly grounded and polarized receptacle. It is the responsibility of the person installing the appliance to assure it is adequately grounded and polarized at the point of installation, taking into consideration local conditions and requirements.
Cycles & Options Qui etSer i es 300 Washing Cycles Heavy Wash Normal Wash Drying Light Wash Rinse Only Options Heating Delay Clean Sanitized Auto Clean START/ Cancel DELAY 1-9 3 Heated Dry Sanitize Tough Scrub Extra Rinse Covers all other models Cycles Options Clean Auto Clean Heavy Wash Normal Wash Light Wash Rinse Only Quick Wash 3 Heated Dry Sanitize Extra Rinse Tough Scrub Plus 160° Wash Sanitized MDB9750 Only See User's Guide for specific operation.
Cycles & Options Qui etSer i es 300 Washing Cycles Heavy Wash Normal Wash Drying Light Wash Rinse Only Options Heating Delay Clean Sanitized Auto Clean START/ Cancel DELAY 1-9 3 Heated Dry Sanitize Tough Scrub Extra Rinse Covers all other models Cycles Options Clean Auto Clean Heavy Wash Normal Wash Light Wash Rinse Only Quick Wash 3 Heated Dry Sanitize Extra Rinse Tough Scrub Plus 160° Wash Sanitized MDB9750 Only See User's Guide for specific operation.
Cycles & Options Qui etSer i es 300 Washing Cycles Heavy Wash Normal Wash Drying Light Wash Rinse Only Options Heating Delay Clean Sanitized Auto Clean START/ Cancel DELAY 1-9 Heated Dry 3 Sanitize Tough Scrub Extra Rinse Covers all other models Cycles Options Clean Auto Clean Heavy Wash Normal Wash Light Wash Rinse Only Quick Wash 3 Heated Dry START/ Cancel Sanitize Extra Rinse Tough Scrub Plus 160° Wash Sanitized DELAY 1-9 Qui etSer i es 300 MDB9750 Only Display Des
Cycles & Options ENN-AIR Washing Cycles Heavy Wash Sanitized Options Clean Drying 2 Normal Wash Light Wash Rinse Only DELAY 2-4-6 START/ Cancel 3 4 Heated Dry Sanitize Tough Scrub Extra Rinse 6 JDB1060 Qui etSer i es 200 Washing Cycles Heavy Wash Normal Wash Light Wash Drying Rinse Only Options Heating Delay Clean Sanitized Auto Clean START/ Cancel DELAY 1-9 3 Heated Dry Sanitize Tough Scrub Plus Extra Rinse MDB8750 Cycles Options Clean Auto Clean Heavy Wash Norm
Electrical-Mechanical Troubleshooting ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. ! CAUTION Units covered in this manual are polarized.
Electrical-Mechanical Troubleshooting ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. Filters Check for blockage of Strainer, Over Pressure Filter. Repair as necessary.
Electrical Mechanical Troubleshooting ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. Thermostat Check mating surface of the High Limit Thermostat face to surface of tub enclosure. Contact area must be flat.
Electrical Mechanical Troubleshooting ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. Will Not Wash Wash Motor Check Wash Motor circuit. See data listed on the Technical Sheet, located behind toe panel.
©2004 Maytag Appliances Company 16022783 Rev.
16022783 Rev.
©2004 Maytag Appliances Company Complete No Is the drain hose going into the plumbing leaking? No Is the incoming water under the sink leaking? B From Page 1 Yes Yes Repair connection 16022783 Rev.
Cycle Selection Problem Troubleshooting Flow Chart 21 16022783 Rev.
©2004 Maytag Appliances Company 16022783 Rev.
Heavy 16022783 Rev.
©2004 Maytag Appliances Company 16022783 Rev.
16022783 Rev.
©2004 Maytag Appliances Company 16022783 Rev.
Yes Yes 16022783 Rev.
©2004 Maytag Appliances Company Yes 16022783 Rev.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. The following paragraphs describe how to disassemble unit under test.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. Wax Motor Detergent / Rinse Dispenser Removal 1. Disconnect power to the machine. 2. Remove the Inner Door Panel.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. Removal 1. Disconnect power to the machine. 2. Remove the Inner Door Panel. (See paragraph Inner Door Panel removal). 3.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. PC Board Technical Sheet Removal The Dishwasher Technical Sheet is located behind the Toe Panel.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. Removal 1. Disconnect power to the machine. 2. Remove Torx™ screw securing Strike to Tub. 5.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. 7. Remove 4 screws securing Control Panel to Outer Door. 8. Remove 4 screws securing Outer Door to Door Hinges.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. Door Spring and Component Replacement Over Pressure Filter NOTE: Always point spring hooks toward the Dishwasher. 1.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. Manifold Docking Station Water is supplied to the Top and Center Wash Arms through this tube via the Pump Assembly.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. 2. Perform continuity check of switch across terminals. Closed- Actuator of switch depressed.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. Thermostats Water Valve Two types of thermostats are used in the Dishwasher. A Thermistor and a Limit Thermostat.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. Checking Valve Operation No Fill 1. Disconnect power to the machine. 2. Remove Support and Toe Panel.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. Replacement Tub Wheels 1. Examine the Air Water Inlet Seal for damage. To remove, unlatch rear Rack Stop.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. 3. Remove Wash Manifold Drain Pump 4. Loosen Wash Arm Hub and Pivot.
Service and Disassembly Procedures ! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational. 15. Remove Chopper Sleeve by using Impeller as a wrench. Lock motor rotation using the access hole provided in back of motor.
Appendix A ©2004 Maytag Appliances Company 16022783 Rev.
Built-In Dishwasher Lavavajillas Empotrado/Lave-vaisselle encastré Installation Instructions/Instrucciones de Instalación/Instructions d’installation Printed in USA ©2003 Maytag Corporation 6 918789 Rev A
Built-In Dishwasher Installation Instructions Leave Installation Instructions and User’s Guide with Owner ALL ELECTRICAL WIRING, GROUNDING AND PLUMBING SHOULD BE DONE IN ACCORDANCE WITH NATIONAL AND LOCAL CODES BY QUALIFIED INDIVIDUALS. E L E C T R I C A L This dishwasher is designed for operation on an individual 120 VAC, 60 Hz grounded electrical circuit. Use required fuse (15 amp) or comparable circuit breaker.
Lavavajillas Empotrado Instrucciones de Instalación Deje las instrucciones de instalación y la guía del usuario con el propietario. TODO EL CABLEADO ELÉCTRICO, LAS CONEXIONES A TIERRA E INSTALACIONES DE PLOMERÍA SE DEBEN REALIZAR CONFORME A LOS CÓDIGOS NACIONALES Y LOCALES POR PERSONAS CUALIFICADAS. R E Q U I S I T O S Este lavavajillas ha sido diseñado para funcionar en un circuito eléctrico individual aprobado de 120 VCA, 60 Hz debidamente conectado a tierra.
Lave-vaisselle encastré Instructions d’installation Laisser les instructions d’installation et le mode d’emploi au propriétaire TOUT LE CÂBLAGE ÉLECTRIQUE, TOUTES LES MISES À LA TERRE, ET INSTALLATIONS DE PLOMBERIE DOIVENT ÊTRE EFFECTUÉS CONFORMÉMENT AU CODE CANADIEN DE L ’ÉLECTRICITÉ ET À TOUS LES CODES DE LA MUNICIPALITÉ EN VIGUEUR PAR DES PERSONNES QUALIFIÉES.
Sound Seals (select models only) Selladores de ruido (ciertos modelos solamente) Joints antibruit (modèles sélectionnés seulement) Toe Panel Seal (select models only) Sello del Rodapiés (ciertos modelos solamente) Joint du socle (modèles sélectionnés seulement) 2 1 2A 2 Mounting Strips (installed on unit) 2 Cintas de Montaje (instaladas en la unidad) 2 bandes de fixation (installées sur l’appareil) Select models only Ciertos modelos solamente Modèles sélectionnés seulement 2B Select models only Cier
3 4 5 6 237⁄8"to 2 3 4 X= Adjusted Foot Height / Altura Ajustada de la Pata / Réglage de la hauteur du pied 7 ⁄8" with no top strip / sin tira de adorno superior / Mesure sans la tringle de finissage 8 1" X 2" H 331/2" 335/8" 333/4" H= Opening Height / H = Altura de apertura / H = Hauteur d’ouverture 9 H : X : 1/4" 337/8" : 3/8" 34" : 1/2" 341/8" H : X : 5/8" 341/4" : 3/4" 343/8" : 7/8" 341/2" H : X : 1" 345/8" : 1/8" 343/4" :11/4" 347/8" H : X : X :13/8" 35" : 13/4" :11/2" 343/4": 11/2" :1
12 11 Installation may vary / Su instalación puede ser diferente / Votre propre installation peut varier 1 2 Refer to local codes / Consulte los códigos locales / Reportez-vous aux codes locaux 13 13A 14 13A 14 13B Panel damage may occur/Puede dañarse el panel/ 15 IMPORTANT/IMPORTANTE Never route cord or hoses under motor / Nunca coloque el cordón eléctrico ni las mangueras por debajo del motor / Ne jamais faire passer câbles ou tuyaux flexibles sous le moteur.
17 18 OFF / APAGADO / ARRÊT 20 19 GROUND/ PUESTA A TIERRA/ MISE À LA TERRE 1 2 4 3 21 BLACK TO BLACK (L1) NEGRO CON NEGRO (L1) FIL NOIR À BORNE NOIRE (L1) 23 GROUND PUESTA A TIERRA MISE À LA TERRE 22 WHITE TO WHITE (NEUTRAL) BLANCO CON BLANCO (NEUTRO) FIL BLANC À BORNE BLANCHE (NEUTRE) 24
25 26 IMPORTANT/IMPORTANTE IMPORTANT/IMPORTANTE 3/16" 3/16" Level left to right Nivele de izquierda a derecha Niveau de gauche à droite Level front to back Nivele del frente hacia atrás N è If not level repeat 24 / Si no está nivelado, repita el paso 24 / En cas de non-nivellement, voir l’étape 24 27 28 29 30 1/8 31 32 IMPORTANT/IMPORTANTE 1/8" IMPORTANT/IMPORTANTE
34 33 1 3 2 4 Turn on water, power and machine / Abra la llave de agua, conecte la corriente y encienda el aparato / Ouvrir le robinet d’eau, l’alimentation et mettre en marche 35 36 Check for leaks, turn off machine / Verifique si hay fugas, apague el aparato / Vérifier l’absence de fuites, mettre à l’arrêt 37 38A 38 Select models only Ciertos modelos solamente Modèles sélectionnés seulement 39 z z z z
39A z z z 40A 40 Select models only Ciertos modelos solamente Modèles sélectionnés seulement z Select models only Ciertos modelos solamente Modèles sélectionnés seulement IMPORTANT/IMPORTANTE
Notes: