User manual

Event Code Tables
A-9
Event Code Tables
Event Code: 072
Message: E_Port connected to unsupported switch.
Severity: Informational.
Explanation: The switch is attached (through an ISL) to an incompatible director or switch.
Action: Disconnect the ISL.
Event Data: No supplementary data included.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
Event Code: 073
Message: Fabric initialization error.
Severity: Informational.
Explanation: An error was detected during the fabric initialization sequence, probably caused by frame delivery errors. Event
data is intended for engineering evaluation.
Action: Perform a data collection and return the CD to support personnel.
Event Data: Byte 0 = error reason code for engineering evaluation.
Bytes 4 - 9 = port numbers where problems were detected.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log