Event Code Tables
Event Code: 426
Message: Multiple ECC single-bit errors occurred.
Severity: Minor.
Explanation: When the SDRAM controller detects an error checking and correction (ECC) error, an interrupt occurs. If an
interrupt occurs a certain number of times weekly, a 426 event code is recorded. The number of interrupts is
indicated by the event data.
Action: No action required. SDRAM is probably malfunctioning intermittently.
Event Data: Byte 0 of the event data (equal to 5, 10, 15, or 20) is recorded. The number of interrupts equals two to the power
of the event data. Event data equal to 10 indicates 1,024 ECC error interrupts.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
Event Code: 433
Message: Nonrecoverable Ethernet fault.
Severity: Major.
Explanation: A non-recoverable Ethernet interface failure was detected and the LAN connection to the management server or
Internet was terminated. No failure information or event codes are reported outside the switch. Although Fibre
Channel port functionality is not affected, the switch cannot be monitored or configured.
Action: Replace the switch.
Event Data: Byte 0 = LAN error type as follows: 01 = hard failure, 04 = registered fault.
Byte 1 = LAN error subtype (internally defined).
Byte 2 = LAN fault identifier (internally defined).
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
✔✔