User manual

Event Code Tables
A-39
Event Code Tables
Event Code: 585
Message: Primitive sequence timeout.
Severity: Major.
Explanation: An attached server recognized either a link reset (LR) protocol timeout or a timeout while waiting for the
appropriate response (while in a NOS receive state and after NOS was not longer recognized).
Action: A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to MAP 0000:
Start MAP to perform fault isolation. In addition, perform a data collection and return the CD to support personnel.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log
Event Code: 586
Message: Invalid primitive sequence received for current link state.
Severity: Major.
Explanation: An attached server recognized either a link reset (LR) or a link-reset response (LRR) sequence while in the
wait-for-online sequence (OLS) state.
Action: A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to MAP 0000:
Start MAP to perform fault isolation. In addition, perform a data collection and return the CD to support personnel.
Event Data: Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution: Product Management Server Host
EFCM Basic
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Log