Specifications

Fibre Channel Switch Requirements
Requirements for Brocade Switches
2-9
Requirements for Brocade Switches
The settings for Brocade switches vary depending upon which UltraNet Edge 3000 configuration is
implemented (E-port Extension or Device Extension [Tape Pipelining]). Use the Brocade settings
shown in the following sections.
Required Brocade Firmware
Table 2-8 provides the required Brocade firmware versions for use with all UltraNet Edge 3000
configurations:
Table 2-8 Required Brocade Firmware
Brocade Model Compatible
Applications
Brocade Series 2000
v2.6.2 v2.6.2a (recommended) for most applications
Brocade 3200 and 3800
v3.1.3a v3.2.0a
v3.2.1 (recommended)
for most applications
Brocade 3250, 3850, 3900, 12000, and 24000
v4.4.2a
v5.0.1b
v5.0.3
v5.1.0b (recommended)
for most applications
Brocade 4100
v5.0.1a
v5.0.3
v5.1.0b (recommended)
for most applications