Specifications

Fibre Channel Switch Requirements
Requirements for Brocade Switches
2-15
switchDomain: 2
switchId: fffc02
switchWwn: 10:00:00:60:69:c0:0b:1b
switchBeacon: OFF
Zoning: ON (Active)
port 0: id 2G Online E_port 20:00:00:00:88:19:71:ca (upstream)
port 1: id N2 No_Light
port 2: id N2 No_Light
port 3: id N2 No_Light
port 4: id N2 No_Light
port 5: -- N2 No_Module
port 6: -- N2 No_Module
port 7: -- N2 No_Module
Switch:admin>
In the preceding output, 2G Online.....E_port 20:00:00:00:88:19:71:ca (upstream)
indicates that a successful E_port has been established. If it was unsuccessful, a world wide name
would not appear and it would say
E_port (no license).
Configuring the Port Settings for Brocade Switch AP7420
The Speed and E_Port Mode should be configured using the following procedure.
It is recommended that the Brocade port connected to the UltraNet Edge 3000 be configured to 1
Gb, as shown in the steps below.
1. Enter the
portcfgspeed command to display the current port speed:
Switch:admin>portcfgspeed 0
Example of the portcfgspeed command screen display:
port 0 speed is: AN
2. Enter the portcfgeport command to display the current E_Port mode:
Switch:admin>portcfgeport 0
Example of the portcfgeport command screen display:
port 0 eport mode is: DISABLED