Specifications

Fibre Channel Switch Requirements
Configuring a Brocade for Use with a UltraNet Edge 3000
2-19
Switch Settings Without the RSL for Use with the UltraNet Edge 3000
Use the following Brocade switch settings with the UltraNet Edge 3000 when you are not using the
Remote Switch License (RSL) and the UltraNet Edge 3000 is configured as E-port Extension.
The BBCredits are not a required configuration on the Brocade switch when configuring the
UltraNet Edge 3000 for E-port Extension (16 is the default).
Flow Control Mode should be set to the default (2) in UCM
Required flash parameters (not using the Remote Switch License):
fabric.domain: 3 (any unique domain)
fabric.ops.E_D_TOV: 5000
fabric.ops.R_A_TOV: 10000
fabric.ops.dataFieldSize: 2112 (default)
fabric.ops.mode.noClassF: 0
fabric.ops.pidFormat: 0 or 1* (see Note)
Note: *The pidFormat may be one or zero depending upon the Brocade switch
Series/model and the firmware level used. The PID setting must be consistent throughout
the fabric, see the “PID Format Settings” section in this chapter.