Fibre Channel Switch Requirements
Brocade Switch Settings Matrix for all Edge Series
2-22 UltraNet Edge Storage Router 3000 Version 3.2 Release Notes
Brocade Switch Settings Matrix for all Edge Series
Table 2-10 shows Brocade switch settings for all Edge models.
Note: The pidFormat may be zero or one depending upon the Brocade series/model and
firmware level used. The PID setting must be consistent throughout the fabric.
Table 2-10 Brocade Switch Settings for all Edge Models
Brocade Switch Settings Edge 3000 Series (FCXL2)
Tape Pipelining (N or NL_port)
Edge 3000 Series (FCBB)
E_port or F_port
fabric.domain:
N/A 3 (any unique domain)
fabric.ops.BBCredit:
7 Not required (16 default)
fabric.ops.E_D_TOV:
2000 5000
fabric.ops.R_A_TOV:
10000 10000
fabric.ops.dataFieldSize:
2048 2112 (default)
fabric.ops.mode.noClassF:
00
fabric.ops.pidFormat:
N/A 0 or 1* (See Note)
Flow Control Mode
(setting in UCM)
N/A With RSL = Set to 3 in UCM
Without RSL = 2