Specifications

Fibre Channel Switch Requirements
Mapping a Device to a Specific E_port Connection
2-23
Mapping a Device to a Specific E_port Connection
The uRouteConfig command can be used to map connections to a specific E_port connection on
the Edge. The following section provides the applicable configuration settings.
The uRoute information is specific to each Brocade switch. Each Brocade switch in the fabric must
be configured with the applicable uRoute information.
For example, a configuration contains an Edge Node10 which has E_port connections in Brocade
ports 0 and 1 in Brocade domain 1. To map a connection from a Brocade to a specific Edge E_port
interface in domain 2, issue the applicable commands from Table 2-11.
Table 2-11 uRouteConfig Commands
2000 series/ Models 3200 and 3800 Models 3250, 3850, 3900, 12000, 24000, and 4100
uRouteConfig 4,2,0
uRouteConfig 5,2,0
uRouteConfig 4 2 0
uRouteConfig 5 2 0
where:
The 1st digit (4 and 5) represents the Brocade port connected to the device(s)
The 2nd digit (2) represents the remote domain
The 3rd digit (0) represents the Brocade port that is being mapped to the UltraNet Edge 3000
Note: For more details on the uRouteConfig command and configuration settings, refer to
the Brocade Fabric OS Reference Manual.