Specifications

Resolved Defects and Known Issues
Known Issues
A-3
Known Issues
There is one known issue for this release. Table A-2 provides a description..
Table A-2 Known Issue
Affected
Customer
Application
Affected
Feature Description Workaround
Product
Defect
Number
Reported
Frequency
Application
Independent
10/100
Ethernet
Support
An old 10/100 Ethernet card
connected directly to a new RoHS
compliant card will not establish a
link if both cards are configured
full duplex.
Set the new RoHS
compliant card to
auto-negotation for
this configuration.
Using UCM:
1. Click the circuit on
the NetMap display.
2. Click the
PPCNode Tab.
3. Click the Ethernet
tab.
4. Look for the
Duplex: field, and
change the selection
from Full to Auto.
If the link will still
not establish reliably,
insert an Ethernet
switch or router set
for auto-negotiation
between the cards.
1-UOIYT Internal