Service manual

Commercial
in
confidence
SMARTFIND
NAVTEX
service
manual
Page
41
Live
System
Operation
2
Test
instruction
Serial
interface
ports
Desired
effect
PASS/FAIL
If
GNSS
(GPS)
or
IBS
is
connected.
Go
to
the
SETUP
MODE,
Serial
o
ptions
page,
Serial
monitor
source,
select
the
correct
serial,
port
View
data
IBS
port
(on
15
way
D
connector
COM1
)
Note
connected
device
type
Printer
NMEA
port
(on
9
way
D
connector
COM
2
)
Note
connected
device
type
Verify
Baud
rate
is
set
correctly
for
each
device
connected.
Baud
rates
(4800),
(38400),
(115200)
Com1
IBS
Port;
Com2
Printer
NMEA
Port;
Ensure
that
the
monitor
window
displays
serial
characters
without
corruption
or
errors
(check
both
ports)
View
data
Pause
monitor
to
freeze
the
updating
Review
data
Note
the
displayed
message
headers
and
relevant
port
used.
RMC,
GLL,
ZDA
GGA
(UTC
and
position)
NRX,
NRQ,
NMK,
ACK,
(NAVTEX)
ALR
(Status
alarm)
Review
data
and
list
the
valid
headers
shown;
IBS
Port;
Printer
NMEA
Port;
Notes;