Specifications

39
General Data - Heat Pump (R22)
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.
MLC 018CR MLC 020CR
Btu/h
18000 19000
W
5280 5570
Btu/h
18500 19500
W
5420 5720
W
1860 1849
W
1700 1799
A
8.4 8.1
A
7.6 7.9
V/Ph/Hz
220 - 240 / 1 / 50 220 - 240 / 1 / 50
W/W
2.84 3.01
W/W
3.19 3.18
l/s / CFM
l/s / CFM
l/s / CFM
EXTERNAL STATIC PRESSURE (H/M/L) mmAq
dBA
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb
mm/in
l/s / CFM
dBA
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb
58 / 128 59 / 130
LIQUID mm/in
GAS mm/in
kg/lb
0.85 / 1.87 1.35 / 2.98
328 / 12.9
EER
COP
OUTDOOR CAP. TUBE
REFRIGERANT CONTROL (EXPANSION DEVICE)
R22
OUTDOOR UNIT
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW
HIGH
REFRIGERANT CHARGE
MCM 020DR
50 / 47 / 40
189 / 400
264 / 560
0
241 / 510
6.4 / 1/4
15.9 / 5/8
INDOOR UNIT
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
MODEL
OUTDOOR UNIT
LOW
INDOOR UNIT
CONTROL
AIR DISCHARGE
NOMINAL RUNNING CURRENT (COOLING)
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
REFRIGERANT TYPE
SOUND PRESSURE LEVEL
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
AIR FLOW
UNIT WEIGHT
CONDENSATE DRAIN SIZE
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
HEIGHT
WIDTH
DEPTH
UNIT DIMENSION
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
1311 / 51.6
670 / 26.3
760 / 29.9
301 / 11.9
614 / 1300
43 / 95
19.1 / 3/4
FLARE VALVE
710 / 28.0
990 / 39.0
415 / 16.3
51
648 / 25.5
855 / 33.7
1214 / 47.8
OPERATION
AUTOMATIC LOUVER (UP & DOWN) & MANUAL LOUVER (BOTTOM)
WIRELESSS OR WIRED MICROCOMPUTER REMOTE CONTROL
214 / 8.42
MEDIUM