Specifications

41
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
General Data - Heat Pump (R22)
MLC 028CR MLC 030CR
Btu/h
26500 30000 / <30000>
W
7770 8790 / <8790>
Btu/h
27000 32000 / <32000>
W
7910 9380 / <9380>
W
2894 2881 / <2861>
W
2674 2921 / <2901>
A
14.3 13.8 / <5.7>
A
13.6 14 / <5.9>
V/Ph/Hz
W/W
2.68 3.02 / <3.07>
W/W
2.96 3.21 / <3.23>
R22 R22
OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE + TXV
l/s / CFM
l/s / CFM
l/s / CFM
EXTERNAL STATIC PRESSURE (H/M/L) mmAq
dBA
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb
mm/in
l/s / CFM
741 / 1570 1605 / 3400
dBA
54 58
mm/in
750 / 29.5 850 / 33.5
mm/in
855 / 33.7 1030 / 40.6
mm/in
328 / 12.9 400 / 15.8
mm/in
810 / 31.9 1000 / 39.4
mm/in
990 / 39.0 1200 / 47.2
mm/in
415 / 16.3 560 / 22.1
kg/lb
68 / 150 95 / 209
LIQUID mm/in
9.5 / 3/8 9.5 / 3/8
GAS mm/in
15.9 / 5/8 15.9 / 5/8
kg/lb
2.18 / 4.81 2.15 / 4.74
EER - 1Ø / <3Ø>
COP - 1Ø / <3Ø>
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
REFRIGERANT CHARGE
220 - 240 / 1 / 50 <380 - 415 / 3 / 50>
FLARE VALVE
670 / 26.3
249 / 9.8
0
AUTOMATIC LOUVER (UP & DOWN) & MANUAL LOUVER (BOTTOM)
WIRELESSS OR WIRED MICROCOMPUTER REMOTE CONTROL
1361 / 53.5
297 / 630
MCM 030DR
INDOOR UNIT
19.1 / 3/4
760 / 29.9
345 / 13.6
1214 / 47.8
51 / 50 / 48
255 / 540
326 / 690
45 / 99
UNIT WEIGHT
UNIT WEIGHT
AIR FLOW
DEPTH
CONDENSATE DRAIN SIZE
UNIT DIMENSION
HEIGHT
WIDTH
UNIT DIMENSION WIDTH
PIPE CONNECTION
TYPE
SIZE
DEPTH
PACKING DIMENSION
HEIGHT
WIDTH
DEPTH
NOMINAL RUNNING CURRENT (COOLING) - 1Ø / <3Ø>
NOMINAL RUNNING CURRENT (HEATING) - 1Ø / <3Ø>
SOUND PRESSURE LEVEL
PACKING DIMENSION
HEIGHT
WIDTH
DEPTH
OUTDOOR UNIT
POWER SOURCE - 1Ø / <3Ø>
HEIGHT
MODEL
OUTDOOR UNIT
SOUND PRESSURE LEVEL (H/M/L)
NOMINAL COOLING CAPACITY - 1Ø / <3Ø>
NOMINAL HEATING CAPACITY - 1Ø / <3Ø>
NOMINAL TOTAL INPUT POWER (COOLING) -1Ø / <3Ø>
NOMINAL TOTAL INPUT POWER (HEATING) - 1Ø / <3Ø>
INDOOR UNIT
MEDIUM
LOW
CONTROL
AIR DISCHARGE
OPERATION
HIGH
AIR FLOW