11.Failure correction notes
If you are not able to clear the failure condition, plea se contact Mean Well o r
any o f our di strib utors fo r repair service.
WARNING :
This is a class A product. In a domesti c environment
this product
ma y ca u se ra di o int erfe ren ce i n wh i c h ca se the u se r ma y be
required to take ade quate measures.
Status
Unable to
cha rge
the battery
LED indicator
doe s not turn
Gre en after a
long charging
period
Possible reasons
ON/OFF switch in th e OFF position Switch to the ON position
Reconnect using the
right polarity
Use battery with the
cor rect voltage
Make sure input sou rce
is between 90~264VAC
Replace with a new
battery
Replace with suitable
wire gauge
Battery reverse polarity
Battery with higher volta ge is
con nected
Input AC vol tage is too low
Battery exceeded lifespan or
damaged
Output cables are too thin
Solutions
10.Serie s and paral lel connection o f batteries
1.Batter ies i n series
2.Batter ies i n parallel
Voltag e can be double d when 2 ba tt eri es ar e c onne cted in seri es. How eve r, th e
Wh en 2 ba tt er ies are c onn ect ed in pa ra ll e l , v olta g e r e ma in s t h e s ame an d th e
capacity (Ah) d oubles. For example , 2 x 12V 100Ah batteries connected i n parallel
= 12V 200Ah.
capacity (Ah) will remain the same. For example, 2 x 12V 100Ah batteries connected
in seri es = 24V 100 Ah.
+
+
+
+