TS-700/1000 Inverter Instruction Manual
TS-700/1000 Inverter Instruction Manual Index 1. Safety Guidelines ............................................................................... 1 2. Introduction ........................................................................................ 1 2.1 Features ......................................................................................... 1 2.2 Main Specification ........................................................................ 2 3. User Interface ...................................
1.Safety Guidelines (Please read through this manual before assembling TS700/1000) Risk of electrical shock and energy hazard. All failures should be examined by the qualified technician. Please do not remove the case of the inverter by yourself! Please do not install the inverter in places with high moisture or near water. Please do not install the inverter in places with high ambient temperature, under direct sunlight or near flame source.
Fully digital controlled including monitoring & display Compliance to UL 458(only TS-1000) / FCC / E 13 / CE Can be used for most electronic products with AC input 3 years global warranty 2.2 Main Specification TS-700 Model Rated O power U T AC voltage P U T Waveform Protection 124 148 212 224 248 112 700W max. continuously, 800W max. for 180 seconds, 1050W max.
C Ventilation holes: The inverter requires suitable ventilation to work properly. Please make sure there is good ventilation and the lifespan of the inverter can be preserved. D Function Setting: Output voltage, frequency, and saving mode can be set through this button. E LED Indicating Panel: Operating status, battery status, load condition, and all kinds of warnings will be displayed on this panel. B C AC Output D Setting ON A Status OFF E Battery Load Remote port Figure 3.1: Front Panel 3.
4.Setup (Output Voltage, Frequency, and Saving Mode) 4.1 Initial State The initial state is 110Vac/60Hz or 230Vac/50Hz and the "Saving Mode" is activated. If users need to revise it for certain application, it can be done the setting button on the front panel (Please refer to section 4.2). The unit will start up automatically after the setting procedure is finished and the new settings will be executed. These new settings will be kept even if the unit is power off/on for any reason. 4.
Note: The above indication will be shown in green STEP 4: The LEDs will change state each time you press the setting button for 1 second and then release (refer to Figure 4.2). Please select the suitable combination of output voltage and frequency you need. 110Vac (220Vac) 50Hz 115Vac (230Vac) 50Hz 120Vac (240Vac) 50Hz 100Vac (200Vac) 50Hz 100Vac (200Vac) 60Hz 120Vac (240Vac) 60Hz 115Vac (230Vac) 60Hz 110Vac (220Vac) 60Hz Figure 4.
5.Protection 5.1 Input Protection (A)Battery Polarity Protection: If the battery input is connected in reverse polarity, the internal fuse of the inverter would blow and the inverter should be send back to MEAN WELL for repair. (B)Battery Under Voltage Protection: When the battery voltage is lower than the preset value, the inverter will automatically terminate the output thus protect the battery from damage. Please refer to Table 5-1 for more detail about the failure signals.
Table 5-1: Failure Messages On Front Panel Failure Message LED Indicator Status Battery Load LED Indicator Failure Message Status Battery Load Abnormal AC Output Voltage Output Overload (105~115% load) Output Overload (115~150% load) Output Overload (150% load) AC Output Short Circuit Abnormal Battery Voltage Over Temperature Light Dark Flashing LED Status Note: The above indication will be shown in red 6.
(C)Requirement of Installation: The unit should be mounted on a flat surface or holding rack with suitable strength. In order to ensure the lifespan of the unit, please refrain from operating in environment of high dust or high moisture. This is a power supply with built-in DC fan. Please make sure that ventilation is not blocked. There should be no barriers within 15cm of the ventilating holes. >15cm Air >15cm Inverter Air Figure 6.
Where, the DC I/P and chassis fix manner as following : 1. Company Name : Mean Well Enterprises Co Ltd 2. Model Name : 1GG1HS-191 3. Rating : 150A 4. Torque : 106.2 Ib.in max. 5. Suitable Wire : Copper wire (temp rating : 75C ) 6. Intended for termination onto a Listed ring tongue connector 7. To Be Sold Only With Installation Instructions 8.
(1)Since inductive loads or motor based equipments need a large start up current (6~10 times of its rated current), the inverter may not start up successfully with these kinds of load. (2)When the output are capacitive or rectified equipments (such as switching power supply), it is suggested to operate these equipment at no load or light load. To ensure proper operation, you should increase the loads only after TS-700/1000 has started up. 7.