User guide
Table Of Contents
- Contents
- Introduction
- The basics
- Entering your settings
- Basic steps
- Setting the time and date
- Selecting the language
- Setting your Alarm/Alert Type
- Entering your glucose monitoring settings
- Turning on the sensor
- Selecting the BG units
- Turning on the Glucose Alerts
- Setting the Glucose Limits
- Setting the Glucose Limits start time
- Setting the High Snooze
- Setting the Low Snooze
- Setting the Predictive glucose alert
- Setting the Rate Alerts
- AUC calculation
- Setting the Alarm Snooze
- Setting the Cal Reminder
- Entering the transmitter identification number
- Setting up the Missed Data option
- Setting the sensor glucose graph timeout
- Reviewing your settings
- Setting up your transmitter and sensor
- Meter option
- Using your system
- Utilities
- Therapy management software
- Troubleshooting and alarms/alerts
- About alarms and alerts
- What to do when you get an alarm/alert
- Sensor alerts
- Viewing your sensor alert history
- System alarms
- Viewing your system alarm history
- Understanding your transmitter, tester, and charger
- Troubleshooting the transmitter
- Troubleshooting the monitor
- My monitor will not display my BG measurement from my meter
- Reconnect old sensor
- Find lost sensor
- What happens if I leave the monitor battery out for more than ten minutes?
- Why doesn't my monitor battery last very long?
- What is a CHECK SETTINGS alarm?
- My screen looks distorted
- I dropped my monitor
- I submerged my monitor in water
- I cannot get to the User Settings screen
- System maintenance
- System specifications
- Alarm/alert types
- Alarm/alert messages and codes
- Alarm/alert history
- Backlight
- Screen and menu timeout
- Sensor glucose graph timeout
- High and low Glucose Limits (CSS7100)
- High and low Glucose Limits (CSS7100K)
- Daily totals
- Default screen
- Default settings
- ENTER BG meter values
- Meter ID entries
- Power supply
- System safety checks
- Radio frequency (RF) communication specifications
- Quality of service
- Data security
- Monitor size
- Monitor weight
- TIME/DATE SET screen
- STATUS screen
- Guidance and manufacturer's declaration
- MiniLink specifications
- Warranty
- Icon table
- Sensor accuracy
- Performance results in adults
- Accuracy of Guardian RT readings
- Precision of Guardian RT readings
- Low and High Alerts in adults
- Guardian RT Sensor Performance and Calibration Stability As a Function of Time
- Effects of calibration frequency
- Performance results in children and adolescents
- Low and High alerts in children and adolescents
- Glossary
- Index
Action: If the alert resulted from two Cal Errors in a row, replace the sensor. If the alert happened
without two Cal Errors, use the transmitter's tester to make sure your transmitter is working properly. If
you received this alert during initialization, you may be able to resolve this alert without replacing your
sensor. Call the 24 Hour HelpLine or your local representative for further assistance.
SENSOR END
Reason: The sensor has reached the end of its life.
Action: Replace your sensor. The sensor has a maximum life of 72 hours (3 days). The 72-hour life span of
the sensor begins when the monitor receives the first METER BG NOW alert.
CAL ERROR
Reason: An error occurred when entering a new meter BG measurement to calibrate the system. Some
possible causes are:
• An incorrect blood glucose measurement was entered from the meter into the monitor.
• The entered blood glucose measurement was not current.
• Your blood glucose is rising or falling rapidly.
• The sensor needs more time to stabilize after being inserted.
• The sensor is no longer reading the sensor glucose correctly.
Action: If you receive a Cal Error, wait until your BG is stable to enter a new meter BG measurement for
calibration. If you receive a Cal Error on your second calibration, a CHANGE SENSOR alert will occur. Call
our 24 Hour HelpLine or your local representative if you have questions.
METER BG NOW
Reason: A meter BG measurement is needed immediately to calibrate the system so that you can continue
receiving sensor glucose measurements.
Action: Take and enter a meter blood glucose measurement.