Table Of Contents
- Contents
- Introduction
- The basics
- Entering your settings
- Basic steps
- Setting the time and date
- Selecting the language
- Setting your Alarm/Alert Type
- Entering your glucose monitoring settings
- Turning on the sensor
- Selecting the BG units
- Turning on the Glucose Alerts
- Setting the Glucose Limits
- Setting the Glucose Limits start time
- Setting the High Snooze
- Setting the Low Snooze
- Setting the Predictive glucose alert
- Setting the Rate Alerts
- AUC calculation
- Setting the Alarm Snooze
- Setting the Cal Reminder
- Entering the transmitter identification number
- Setting up the Missed Data option
- Setting the sensor glucose graph timeout
- Reviewing your settings
- Setting up your transmitter and sensor
- Meter option
- Using your system
- Utilities
- Therapy management software
- Troubleshooting and alarms/alerts
- About alarms and alerts
- What to do when you get an alarm/alert
- Sensor alerts
- Viewing your sensor alert history
- System alarms
- Viewing your system alarm history
- Understanding your transmitter, tester, and charger
- Troubleshooting the transmitter
- Troubleshooting the monitor
- My monitor will not display my BG measurement from my meter
- Reconnect old sensor
- Find lost sensor
- What happens if I leave the monitor battery out for more than ten minutes?
- Why doesn't my monitor battery last very long?
- What is a CHECK SETTINGS alarm?
- My screen looks distorted
- I dropped my monitor
- I submerged my monitor in water
- I cannot get to the User Settings screen
- System maintenance
- System specifications
- Alarm/alert types
- Alarm/alert messages and codes
- Alarm/alert history
- Backlight
- Screen and menu timeout
- Sensor glucose graph timeout
- High and low Glucose Limits (CSS7100)
- High and low Glucose Limits (CSS7100K)
- Daily totals
- Default screen
- Default settings
- ENTER BG meter values
- Meter ID entries
- Power supply
- System safety checks
- Radio frequency (RF) communication specifications
- Quality of service
- Data security
- Monitor size
- Monitor weight
- TIME/DATE SET screen
- STATUS screen
- Guidance and manufacturer's declaration
- MiniLink specifications
- Warranty
- Icon table
- Sensor accuracy
- Performance results in adults
- Accuracy of Guardian RT readings
- Precision of Guardian RT readings
- Low and High Alerts in adults
- Guardian RT Sensor Performance and Calibration Stability As a Function of Time
- Effects of calibration frequency
- Performance results in children and adolescents
- Low and High alerts in children and adolescents
- Glossary
- Index
The accuracy of the Guardian RT was also evaluated by calculating the percentage of Guardian RT
readings within 20% and within 30% of the blood glucose meter reading (or within 20 mg/dL (1.1 mmol/L)
in the low glucose range). Results are shown in the following table.
Plasma Glucose
Range (mg/dL)
Plasma Glucose
Range (mmol/L)
Number of Paired
Readings
Percent Within
20%
Percent Within
30%
Overall 2599 68% 82%
40-80* 2.2-4.4 360 51% ----
> 80-120 > 4.4-6.7 482 60% 77%
> 120-240 > 6.7-13.3 1055 74% 90%
> 240 > 13.3 702 75% 89%
*For the Low glucose range, 40-80 mg/dL (2.2-4.4 mmol/L), the value shown is the percent within 20
mg/dL (1.1 mmol/L).
The Clarke Error Grid was used to assess the clinical relevance of the differences between the Guardian RT
readings and the comparative blood glucose meter measurements. The Clarke Error Grid divides a
correlation plot into 5 zones. See the following table.
Results in zones A and B are considered clinically acceptable, while results in zones C, D, and E are
potentially dangerous and, therefore, clinically significant errors. The Clarke Error Grid zones are labeled
on the correlation plot.
Zone Description
A Clinically accurate, would lead to correct treatment decisions
B Would lead to benign decisions or no treatment
C Would lead to over-correction of normal glucose levels
D Would lead to failure to detect and treat high or low glucose levels
E Would lead to erroneous treatment decisions
Sensor accuracy 149
Appendix A