User guide
Table Of Contents
- Contents
- Introduction
- The basics
- Entering your settings
- Basic steps
- Setting the time and date
- Selecting the language
- Setting your Alarm/Alert Type
- Entering your glucose monitoring settings
- Turning on the sensor
- Selecting the BG units
- Turning on the Glucose Alerts
- Setting the Glucose Limits
- Setting the Glucose Limits start time
- Setting the High Snooze
- Setting the Low Snooze
- Setting the Predictive glucose alert
- Setting the Rate Alerts
- AUC calculation
- Setting the Alarm Snooze
- Setting the Cal Reminder
- Entering the transmitter identification number
- Setting up the Missed Data option
- Setting the sensor glucose graph timeout
- Reviewing your settings
- Setting up your transmitter and sensor
- Meter option
- Using your system
- Utilities
- Therapy management software
- Troubleshooting and alarms/alerts
- About alarms and alerts
- What to do when you get an alarm/alert
- Sensor alerts
- Viewing your sensor alert history
- System alarms
- Viewing your system alarm history
- Understanding your transmitter, tester, and charger
- Troubleshooting the transmitter
- Troubleshooting the monitor
- My monitor will not display my BG measurement from my meter
- Reconnect old sensor
- Find lost sensor
- What happens if I leave the monitor battery out for more than ten minutes?
- Why doesn't my monitor battery last very long?
- What is a CHECK SETTINGS alarm?
- My screen looks distorted
- I dropped my monitor
- I submerged my monitor in water
- I cannot get to the User Settings screen
- System maintenance
- System specifications
- Alarm/alert types
- Alarm/alert messages and codes
- Alarm/alert history
- Backlight
- Screen and menu timeout
- Sensor glucose graph timeout
- High and low Glucose Limits (CSS7100)
- High and low Glucose Limits (CSS7100K)
- Daily totals
- Default screen
- Default settings
- ENTER BG meter values
- Meter ID entries
- Power supply
- System safety checks
- Radio frequency (RF) communication specifications
- Quality of service
- Data security
- Monitor size
- Monitor weight
- TIME/DATE SET screen
- STATUS screen
- Guidance and manufacturer's declaration
- MiniLink specifications
- Warranty
- Icon table
- Sensor accuracy
- Performance results in adults
- Accuracy of Guardian RT readings
- Precision of Guardian RT readings
- Low and High Alerts in adults
- Guardian RT Sensor Performance and Calibration Stability As a Function of Time
- Effects of calibration frequency
- Performance results in children and adolescents
- Low and High alerts in children and adolescents
- Glossary
- Index
![](/manual/medtronic/guardian-real-time/user-guide-english/images/img-64.png)
Entering Other markers
This section shows you how to enter markers other than Enter BG, Insulin Marker, Meal Marker, or Exercise
Marker. When you enter Other markers, you only enter the type of marker (Other); the time is
automatically recorded by the system. Examples of Other markers include: when you take medications,
when you feel ill, when you are under stress, etc. These markers then create reports that appear with the
name of the marker (Other) and the time you entered it.
To enter Other markers:
1 Go to the OTHER screen.
Main > Capture Event > Other
A message appears: Do you want to enter an Other marker?
2 Select Yes, then press ACT. Your monitor saves your Other marker and returns to the CAPTURE EVENT
screen.
Reading the sensor glucose graphs
Your monitor shows an updated, real-time glucose value every five minutes. This value is generated by
data sent from the sensor to the transmitter, and then to the monitor, where it is converted to a glucose
value shown as 3, 6, 12 and 24 hour graphs. Make sure your graph screen does not say DEMO in the upper
left corner. If it does, you must turn the Sensor Demo off. The graphs include the following information:
• The most recent sensor glucose or the reason that a sensor glucose value is not displayed.
• The historical sensor glucose value taken for the last 3, 6, 12 or 24 hours, including the value and the
time the sensor glucose value was taken, or the reason it is not displayed.
• Arrows that show the relative rate at which the most recent sensor glucose levels are rising or falling.
Your monitor does not alert every time it does not receive an SG value. Therefore your alarm or alert
history may not match the number of times your graphs do not show an SG value. The following conditions
can prevent a real-time sensor glucose value from being displayed:
•A Lost Sensor alert.
•A Sensor Error alert.
•A Change Sensor alert.
•A Cal Error alert.
• Find Lost Sensor (15 minutes).
•Weak Signal.
Using your system54