Product specifications

530.PROD.GB.3 : 530.INST.CONFIG.KEYPAD.NONE.GB.1 Black 14
14©, MEI., 1994.
CashFlow
530 Changegiver Product Maintenance Handbook
coins from the selected tubes in the same way as described above.
Latched dispense will continue on each tube until each tube reaches
its safe coin level.
Setting Prices
The main principle of price teach is that selections will have their
prices set to the accumulated credit value. To use this mode:
1 Press the mode key on the keypad
2 Press key C. Any stored credit will be cleared and a
time-out period of 45 seconds will start. The time-out
period restarts after every accepted coin.
3 Enter coins through the acceptor until the value of the
price to be set has been reached. The value of any coins
entered will be accumulated as credit and will be
displayed on the credit display, if fitted.
4 Press the vend button on the machine corresponding to
the selection price. The price has now been set.
5 Press key C on the keypad to return to normal operation.
Coins to the value of the price set will be returned. If you
do not press the C key, then 45 seconds after the last
coin was entered, the unit will automatically return to
normal operation and credit will be returned.
The above stages can be repeated for any selection you wish to
change the price of. If a number of selections are required to be set
to the same price you only need to accumulate the credit value
once. You can then press the appropriate selection buttons on the
machine. If more than one price has to be set then accumulate the
lowest credit value first, set the price, and then add further coins to
the next highest value and set that price etc.
Note: Prices of 0 cannot be set.
On Executive and BDV variants, the prices are not normally held in
the changegiver and are therefore inaccessible to this form of
update unless price holding mode is enabled via the MEI
Route
Alpha 250 Terminal, and the vending machine is able to support
price holding operation.