Automatic Tube Float
To refill the coin tubes (float up) to their pre-programmed float levels
follow the instructions below.
1Press the mode key on the keypad.
2Press key A. Any stored credit will be cleared and a
time-out period of 45 seconds will start. The time-out
period restarts after every accepted coin.
3Enter coins through the acceptor. The changegiver will
automatically accept only the amount of coins needed to
reach the required float level in that tube. Any
subsequent coins will be rejected. Any coins entered will
be accumulated as credit and will be displayed on the
credit display, if fitted.
4Press key A on the keypad, it will clear any credit and
return to normal operation.
NOTE: When the tube is empty, the first coin may pass straight
through. If this occurs, remove the coin from the machine return cup
and put it back directly into the tube using the manual fill facility as
described earlier.
You can also reset the float levels using the MEI
Route Alpha 250
terminal.
Coins can be filled above the pre-set float level in each tube outside
of the product. When the cassette is refitted and the dispense keys
are pressed, coins will stop dispensing when each tube reaches its
safe coin level. The changer can then be floated in the normal way.
Automatic Tube Inventory
This function allows you to automatically dispense (i.e. float down)
all excess coins from each of the tubes. Change coins continue to
be routed to the tubes rather than the cashbox when the preset float
level has been reached.
1 Press the mode key.
2 Press key A followed by key C.
All coins above the preset float level will automatically dispense
from the tubes, and will stop when the pre-programmed float level
has been reached.