Product specifications

530.PROD.GB.3 : 530.INST.CONFIG.CF_850.NONE.GB.2 Black,White 23
©, MEI., 1994.23
CashFlow
530 Changegiver Product Maintenance Handbook
252 Tube B float level 0 - 255 as address 251
253 Tube C float level 0 - 255 as address 251
261
Tube in position A full
count
0 - 255
number of coins in a tube
that activate the full sensor
262 Tube B full count 0 - 255 as address 261
263 Tube C full count 0 - 255 as address 261
271
Tube in position A low
count
0 - 255
number of coins in a tube
that activate the low sensor
272 Tube B low count 0 - 255 as address 271
273 Tube C low count 0 - 255 as address 271
281
Tube in position A
safe count
0 - 7
minimum number of coins
that must be left in a tube
(this number is multiplied by
2 in the changer)
282 Tube B safe count 0 - 7 as address 281
283 Tube C safe count 0 - 7 as address 281
291 1st coin type in tube A 0 - 12
coin number 0 = no coin
(taken from coinset label
reading from left to right &
top to bottom)
292 1st coin type in tube B 0 - 12 as address 291
293 1st coin type in tube C 0 - 12 as address 291
301
2nd coin type in tube
A
0 - 12 coin number, 0 = no coin
302
2nd coin type in tube
B
0 - 12 coin number, 0 = no coin
303
2nd coin type in tube
C
0 - 12 coin number, 0 = no coin
310
Value of coins in
tubes READ ONLY
0-65,535 value of coins in all tubes
311
tube A current coin
count READ ONLY
0 - 255
current number of coins in
tube
Address
Parameter
Range
Meaning