Product specifications

530.PROD.GB.3 : 530.GEN.MOD_XCHNG.STORE.NONE.GB.1 Black,White 39
©, MEI., 1994.39
CashFlow
530 Changegiver Product Maintenance Handbook
DESIGNATOR AND COIN THICKNESS
ADDING A NEW COIN
If you have added a new coin to the coinset you must establish and
reset the following addresses using the MEI
Route Alpha 250
terminal;
Tube Low Counts - addresses 271-273
Minimum Safe Counts - addresses 281-283
Tube Full Counts - addresses 261 -263
SETTING THE TUBE LOW COUNTS
1 Set the tube low count number to 3 (address 271 - 273
depending on the tube).
2 Set the minimum safe count number to 1 (address 281 -
283 depending on the tube).
3 Fill the tube with coins up to at least 25% of the total tube
capacity.
4 Press the mode key then A key followed by the B key on
the keypad. (This will set the coin count to its preset coin
level).
5 Press the appropriate dispense button and hold for
approx 3 seconds to ‘latch’ the dispenser.
6 After the dispenser has stopped returning coins count
the coins that are left in the tube.
Designator
Nominal
Designator
Thickness
Minimum Coin
Thickness
Maximum Coin
Thickness
A (RED) 1.0 3.16 3.60
B (ORANGE) 1.55 2.66 3.15
C (YELLOW) 2.05 2.18 2.65
D (GREEN) 2.48 1.81 2.17
E (BLUE) 2.80 1.56 1.80
F (VIOLET) 3.05 1.36 1.55
G (BLACK) 3.25 1.21 1.35
H (WHITE) 3.40 1.10 1.20