REMOVING THE KEYPAD AND TRANSFORMER
Remember to switch off the machine.
The keypad and its housing also provides protection for the
transformer assembly.
1 Remove the coin storage cassette and the acceptor as
shown in the previous pages.
2 Push the back of the cover flap downwards until it
latches in the open position.
3 Remove the fixing screw which you can now see under
the front edge of the cover flap.
4 Ease the keypad and cover towards you.
When you have removed the cover you can access the transformer
assembly. The transformer is connected to the control board via two
looms. To remove it, disconnect the two looms and lift the
transformer out of its housing.
Fixing Screw
Push the cover flap here